MAN 650067:G
20
Display update setup (UPDATE)
The display update rate can be adjusted so the reading on the tachometer doesn’t
change so quickly. This is a personal preference and is used to “slow” the reading by
averaging. The value can be changed from slow, mid, or fast.
When “UPDATE” is displayed, press and hold SW1 until you get “ - ”.
Release SW1 and the current update rate will be displayed.
Press and release SW1 to increase the value from “SLOW” “ MIDFAST”.
When the desired setting is displayed, press and hold SW1 until “ - ” “DONE” is displayed.
Release the switch to go onto the next sub-menu item.
RPM warning setup (WARN)
This is used for the turn on point for the WARN output on the control box. When the
RPM reading is above this setting, the output will activate, providing a ground signal. It can be
used to turn on a shift light or other RPM based devices. The value is adjustable from 2200
RPM – 14800 RPM in 100 RPM increments.
When “WARN” is displayed, press and hold SW1 until you get “ - ”.
Release SW1 and the current warning point will be displayed.
Press and release SW1 to increase the value from “W 2200” – “W14800”.
When the desired setting is displayed press and hold SW1 until “ - ” “DONE” is displayed.
Release the switch to go onto the next sub-menu item.
Tach signal setup (SIGNAL)
This menu will allow you to select from two different tach-input types. A low voltage, “5
LO”, tach signal or a high voltage tach signal, “12 HI”. A low voltage signal is usually one
picked up from the ECM. Low voltage may also be considered a 0-5V square wave. If you are
getting the tach signal from the ignition coil or points, set this for the high voltage signal “12 HI”.
To pick up a tach signal from a traditional coil, wire the tach input to the negative side of the coil.
When “SIGNAL” is displayed press and hold SW1 until you get “ - ”.
Release SW1 and the current value will be displayed.
Press and release SW1 to toggle from “12 HI” to “5 LO”.
When the desired setting is displayed, press and hold SW1 until “ -” “DONE” is displayed.
Release the switch to go onto the next sub-menu item.
Exit tach setup (DONE)
This will allow you to exit the tach setup and go on to the next setup menu.
When “Se
SeSe
Set
DONE” is displayed, press and hold SW1 until you get “ -” “DONE”.
Release the switch to go onto the next menu .
VOLT SETUP
The Volt setup allows you set a warning point that will cause the Volt display to flash
whenever the voltage drops below the warning value. The low voltage point can be set from 10
-13.1 volts.
Press and hold SW1 while turning the key on.
Release the switch and then press and release SW1 to get to the “VOLT” setup menu.
When “VOLT” is displayed press and hold SW1 until you get “ - ”, release SW1 and “WARN
will be displayed.
When “WARN” is displayed, press and hold SW1 until you get “ - ”.
Release SW1 and the current warning point will be displayed.
Press and release SW1 to increase the value from “LO 10.0” – LO 13.1”.
When the desired setting is displayed, press and hold SW1 until “ - ” “DONE” is displayed.
Release the switch to go onto the next sub-menu item.
Page view 19